(Portable Appliance Tester and Checker). Performs electrical safety tests on portable appliances allowing compliance with EAWA regulations. The unit performs earth bond and insulation tests on both Class 1 and Class 2 appliances, extension leads, IEC and kettle leads etc. The unit is very simple to operate and gives clear, unambiguous pass/fail indications. Complete with test leads, instructions, pass and fail labels, a Tester’s Certificate of Inspection and is fitted with moulded mains plug.

Description

A simple to use PAT machine that allows the user to perform Class1 and Class 2 insulation tests, earth bond tests at two different current levels and extension lead tests. The compact unit clearly displays the results via coloured LEDs. A single push button initiates all the tests in a 5-second cycle.

•Class 1 Earth Bond test
•Class 1 and Class 2 Electrical Insulation test
•Mains switch and circuitry test
•Extension Lead test
•IEC lead test
•Results are displayed by coloured LEDs.  Timed test period.

Comes complete with 100 pass labels, 50 fail labels, Earth Bond Test lead, Extension lead test lead and full instructions including sample inspection certificate.

Quick Comparison

SettingsPortable Appliance Tester & Checker - PATCH removeIrwin Powerswitch removeMini National Grid remove24V 21W Small Bayonet Cap Radial Filament Lamp removeBrass Small Bayonet Cap Batten Holders - Oval base removePowerlock Gratnells Tray Pack of 4 remove
NamePortable Appliance Tester & Checker - PATCH removeIrwin Powerswitch removeMini National Grid remove24V 21W Small Bayonet Cap Radial Filament Lamp removeBrass Small Bayonet Cap Batten Holders - Oval base removePowerlock Gratnells Tray Pack of 4 remove
Image
SKU
Rating
Price
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

Description

Code: EPT5001

(Portable Appliance Tester and Checker). Performs electrical safety tests on portable appliances allowing compliance with EAWA regulations. The unit performs earth bond and insulation tests on both Class 1 and Class 2 appliances, extension leads, IEC and kettle leads etc. The unit is very simple to operate and gives clear, unambiguous pass/fail indications. Complete with test leads, instructions, pass and fail labels, a Tester's Certificate of Inspection and is fitted with moulded mains plug.

Code: EPU0113

A compact power supply offering 2, 4, 6, 8, 10, and 12 volts at currents of up to 5A. Both dc and ac outputs may be used simultaneously up to the rated output. The output is protected by a push button cut-out. The unit is 2A fused on the back panel and comes complete with a moulded mains lead and plug. 4 units are designed to fit in a shallow Gratnell tray.

Other equipment needed is two standard 4mm plugged leads and a power supply capable of delivering 2-3 volts at 1 amp.
Pack of 10 24V 21W Small Bayonet Cap (SBC) Radial Filament Lamps.
Class Packs of Brass SBC (Small Bayonet Cap) round lamp holders with an oval base.

Code: EPU0115PK4

Our compact Powerlock power supply now comes supplied in a 4 pack with a Gratnells deep tray for ease of storage. Offering 2, 4, 6, 8, 10, and 12 volts at currents of up to 5A. Both dc and ac outputs may be used simultaneously up to the rated output. The output is protected by a push button cut-out. The unit is 2A fused on the back panel and comes complete with a moulded mains lead and plug. Supplied with 2 keys.
Content
A simple to use PAT machine that allows the user to perform Class1 and Class 2 insulation tests, earth bond tests at two different current levels and extension lead tests. The compact unit clearly displays the results via coloured LEDs. A single push button initiates all the tests in a 5-second cycle. •Class 1 Earth Bond test •Class 1 and Class 2 Electrical Insulation test •Mains switch and circuitry test •Extension Lead test •IEC lead test •Results are displayed by coloured LEDs.  Timed test period. Comes complete with 100 pass labels, 50 fail labels, Earth Bond Test lead, Extension lead test lead and full instructions including sample inspection certificate.
Specification 
  • Input Supply voltage 230V dc 
  • Supply frequency 50Hz 
  • Mains fuse Rear panel 2A, 20mm quick blow Mains plug 3A 
  • Output Voltage 2, 4, 6, 8, 10, 12V ac nominal 1, 3, 5, 7, 9, 11V full wave rectified dc nominal
  • Maximum output current 5A ac or dc
  • Manufactured in the UK

Code: ENG1050

Our mini national grid system is a very cost-effective way of teaching the principles used by the National Grid to supply electrical power to our homes. This kit comprises two printed circuit boards and a set of "HT" leads to interconnect them and is SELV (Safety /Separated Extra Low-Voltage) classed, which means that no part of the system is at more than 50 volts - which means it is very safe and suitable for student use. The system allows the user to compare electrical transmission at low and high voltages and the results are displayed by the brightness of the two on-board MES lamps which are supplied.

Code: OPR1221

Pack of 10 24V 21W Small Bayonet Cap (SBC) Radial Filament Lamps.

Code: OPB3005

Class Packs of Brass SBC (Small Bayonet Cap) round lamp holders with an oval base.
  • A robust power supply for powering laboratory experiments.
  • Heavy duty toroid transformer
  • Small footprint - 4 units fit in a Gratnells deep tray
  • Powder coated steel case
  • Switched output of 2V, 4V, 6V, 8V, 10V and 12V ac/dc controlled by a key lock
  • Two keys supplied with each Powerlock. Common key profile – any key fits any Powerlock
  • Total output current of 5A
  • AC and DC outputs may be used simultaneously up to rated current
  • Colour coded 4mm sockets
  • Push button cut-out
  • Manufactured in the UK