Description
Code: EPT5001LDS
Additional spare or replacement leads for our Portable Appliance Tester and Checker.
Additional spare or replacement leads for our Portable Appliance Tester and Checker.
Code: EPT5001LDS
Additional spare or replacement leads for our Portable Appliance Tester and Checker.
Settings | Irwin Portable Appliance Tester (PATCH) leads remove | Irwin Powerswitch remove | Portable Appliance Tester & Checker - PATCH remove | Planck's Constant LED Apparatus remove | Brass Small Bayonet Cap Batten Holders - Oval base remove | Dual Output PSU (12VAC/12VDC) remove |
---|---|---|---|---|---|---|
Name | Irwin Portable Appliance Tester (PATCH) leads remove | Irwin Powerswitch remove | Portable Appliance Tester & Checker - PATCH remove | Planck's Constant LED Apparatus remove | Brass Small Bayonet Cap Batten Holders - Oval base remove | Dual Output PSU (12VAC/12VDC) remove |
Image | ||||||
SKU | ||||||
Rating | ||||||
Price | ||||||
Stock | ||||||
Availability | ||||||
Add to cart | ||||||
Description |
Additional spare or replacement leads for our Portable Appliance Tester and Checker.
| Code: EPU0113 A compact power supply offering 2, 4, 6, 8, 10, and 12 volts at currents of up to 5A. Both dc and ac outputs may be used simultaneously up to the rated output. The output is protected by a push button cut-out. The unit is 2A fused on the back panel and comes complete with a moulded mains lead and plug. 4 units are designed to fit in a shallow Gratnell tray. | Code: EPT5001
(Portable Appliance Tester and Checker). Performs electrical safety tests on portable appliances allowing compliance with EAWA regulations. The unit performs earth bond and insulation tests on both Class 1 and Class 2 appliances, extension leads, IEC and kettle leads etc. The unit is very simple to operate and gives clear, unambiguous pass/fail indications. Complete with test leads, instructions, pass and fail labels, a Tester's Certificate of Inspection and is fitted with moulded mains plug.
| Code: EPC7000
A multipurpose unit that allows the user to easily calculate Planck's constant, to measure the wavelength of coloured light, demonstrate colour light transmission through colour filters and show the diffraction patterns for various wavelengths of coloured light using a range of 4 LEDs (Red, Yellow, Green and Blue) covering the light range from deep blue at 470nm to near IR at 940nm.
|
Class Packs of Brass SBC (Small Bayonet Cap) round lamp holders with an oval base.
| Code: IPC-1402-P
This instrument (IPC-1402-P) is designed as a general purpose laboratory power supply. It has two isolated outputs which operate independently of each other.
The AC output is selected by means of a 4-position switch on the front panel. Selected voltages are 2, 4, 6 and 12V at 4A continuously, or up to 5A for periods of 1 hour. The output is supplied via a pair of 4mm sockets on the front panel colour coded white. The output is protected from overload or short circuit by a current sensing circuit breaker mounted on the front panel.
The DC output is smoothed and regulated and is continuously variable from 0V to 12V at currents up to 3A. Voltage ripple typically less than 50mV. The output is supplied via a pair of 4mm sockets on the front panel colour coded red (positive) and black (negative). The output is protected from short circuit or overload by an electronic regulator.
The outputs may be used simultaneously as long as the combined load does not exceed 3A.
Power on is indicated on the front panel by a green LED. An illuminated on/off switch is mounted on the rear panel adjacent to a fused IEC mains inlet. Enclosed in a robust metal case with a durable powder coated finish. Supplied with detachable mains lead and instructions.
A pair of graphs showing how the output voltage of this power supply varies as the current supplied is increased is included in the instruction leaflet for this instrument.
|
Content | Code: EPT5001LDS
Additional spare or replacement leads for our Portable Appliance Tester and Checker.
|
Specification
|
A simple to use PAT machine that allows the user to perform Class1 and Class 2 insulation tests, earth bond tests at two different current levels and extension lead tests. The compact unit clearly displays the results via coloured LEDs. A single push button initiates all the tests in a 5-second cycle.
•Class 1 Earth Bond test
•Class 1 and Class 2 Electrical Insulation test
•Mains switch and circuitry test
•Extension Lead test
•IEC lead test
•Results are displayed by coloured LEDs. Timed test period.
Comes complete with 100 pass labels, 50 fail labels, Earth Bond Test lead, Extension lead test lead and full instructions including sample inspection certificate.
| Box mounted with 5 x 4mm sockets for attachment to an ammeter or voltmeter to display measurements. Monitoring the voltage of each LED a graph of energy input as a function of light frequency emitted can be measured with an approximate value of Plank's constant calculated.
| Code: OPB3005
Class Packs of Brass SBC (Small Bayonet Cap) round lamp holders with an oval base.
|
Description: Dual Output PSU (12VAC/12VDC)
Part Number: IPC-1402-P
Electrical Supply: 220-240VAC, 50-60Hz
Dimensions: 179 x 190 x 85mm overall
Mass: 2.9kg
AC Output Voltage Range: 2, 4, 6 and 12VAC
Maximum AC Output Current: 4A (5A upto 1 hour)
DC Output Voltage Range: 0 to 12VDC
Maximum DC Output Current: 3A
|